Direct Current: What is it? (AC vs DC & DC Current Symbol)

What is DC Current
💡
Key learnings:
  • Direct Current Definition: Direct current is a constant and unidirectional flow of electric charge, moving from a negative to a positive terminal.
  • AC vs DC: Direct current flows in one direction and is used in applications requiring stable voltage, while alternating current can reverse direction and is typically used where varying power levels are needed.
  • DC Current Symbol: The symbol for DC current is a straight line, indicative of its consistent and unchanging direction.
  • Measurement Techniques: DC current is measured using a multimeter or a clamp-on meter, which assesses the flow of electricity through a circuit.
  • Historical Evolution: DC was pioneered by innovators like Alessandro Volta and Thomas Edison, and although initially predominant, AC became favored for long-distance power transmission.

What is DC Current?

DC stands for direct current, so “DC current” is a common but redundant phrase. Direct current is the unidirectional flow of electric charge. Its magnitude may be steady or may vary without reversing polarity. In an alternating current circuit, polarity and current direction reverse periodically.

Direct current can pass through a conducting material such as metal and through semiconductors when a complete circuit and suitable voltage are present.

A battery converts chemical energy into electrical energy and maintains a DC terminal polarity. In the external circuit, conventional current flows from the positive terminal to the negative terminal; electron drift in a metal is opposite.

A rectifier converts AC to DC. An inverter converts DC to AC.

DC Current Symbol

DC does not have to be constant; pulsating DC remains unidirectional. The common DC symbol uses a solid horizontal line above a dashed line, while the AC symbol is a sine-wave form. The figure shows these supply-type symbols.

Symbol of DC and AC Current
Symbol of DC and AC Current

Difference between AC and DC Current

Electrical systems can use alternating current or direct current. A 50 Hz AC waveform completes 50 cycles each second; a 60 Hz waveform completes 60. Its polarity reverses during every cycle according to its frequency.

The main differences between AC and DC are summarized in the table below:

Alternating Current (AC) Direct Current (DC)
The direction of flow of current Current direction reverses periodically. Current retains one direction, although its magnitude may vary.
Frequency Frequency is cycles per second; polarity reverses within each cycle. Steady DC is treated as 0 Hz. Pulsating DC can contain ripple frequencies without reversing direction.
Movement of Electron Electron drift in a metal alternates with the electric field. Electron drift has one mean direction in a metal circuit.
Current magnitude Instantaneous magnitude usually varies with time. Pure DC is constant; pulsating DC varies without changing sign.
Power Factor Depends on load impedance and waveform. Power factor is an AC concept and is not normally assigned to steady DC.
Passive Parameter Impedance combines Reactance and Resistance. Steady-state DC sees resistance; inductors and capacitors also control transients.
Types Sinusoidal and non-sinusoidal periodic waveforms Steady DC and pulsating DC
Transmission of electrical energy HVAC is widely used in a power system because transformers and switchgear are established. The best choice depends on distance and project conditions compared with an HVDC transmission system. HVDC can reduce long-distance line losses and connect asynchronous grids, but converter stations add cost and loss.
Convert A rectifier converts AC to DC. An inverter converts DC to AC; DC also supplies phones, vehicles and electroplating.
Type of load AC can supply resistive, inductive and capacitive loads. DC can supply resistive loads and circuits containing inductors or capacitors, subject to switching transients.
Source Alternators, inverters and the grid DC Generator, batteries, solar cells and rectifiers
Dangerous AC can cause shock, burns and arc hazards. DC can cause shock, burns and sustained arcs. Risk depends on voltage, current path, duration and source energy.
Waveform Waveform of AC Current Waveform of DC Current
Application Grid distribution and many household, industrial and commercial loads use AC.Phones, electric vehicles, Electroplating, electronic circuits and battery systems use DC.
Table comparing Direct Current To Alternating Current

What Uses DC Current?

Batteries and solar cells provide DC. Many power-electronic circuits use an internal DC link even when their input or output is AC. Applications include:

  • Low-voltage DC supplies charge batteries and power electronics, emergency lighting and security equipment.
  • In a combustion vehicle, the battery supplies starting, lighting and control systems. Electric vehicles store DC energy but usually drive AC or electronically commutated motors through power converters.
  • Telecommunications sites commonly use a 48V DC supply is used, often with a grounded reference. Actual return conductors and grounding follow the equipment and installation standard.
  • HVDC can be more efficient and economical than HVAC for sufficiently long links. It avoids AC charging current and corona effect differs between designs, while DC avoids AC skin effect. It does not eliminate conductor, corona or converter losses.
  • Photovoltaic modules in a solar power plant produce DC, which an inverter converts to AC for an AC grid.
  • Electrical energy is stored in chemical, electric, magnetic, mechanical or thermal form rather than as “AC” or “DC”. Many battery and capacitor systems expose a DC electrical interface.
  • Rail traction can use AC or DC electrification and AC or DC motors. Modern locomotives often use a DC link and inverters, while auxiliary systems use several voltage types.

How To Measure DC Current

A multimeter measures DC current by becoming part of the circuit in series with the load. De-energise the circuit before opening it, use the correct fused input and range and never place a meter in current mode directly across a voltage source.

For a positive reading in the illustrated low-side connection, current enters the red current terminal and leaves COM. Lead placement depends on where the circuit is opened. Follow the meter manual, its category rating and the circuit’s safe isolation procedure.

Measure DC Current
Measure DC Current

Select the DC current function and a range above the expected current. A DC-capable clamp meter can measure without opening the circuit; zero it as instructed and clamp around one conductor only.

Which Way Does DC Current Flow?

Electric current is net charge flow. Conventional current direction follows positive charge, regardless of which charge carriers move.

In the external metallic circuit of a discharging battery, electrons drift from the negative terminal towards the positive terminal. Conventional current is defined in the opposite direction.

Benjamin Franklin established positive and negative charge terminology before electrons were discovered. Current through a metal conductor is carried mainly by electrons, not protons.

The later conventional-current definition follows the direction positive charge would move, from higher potential to lower potential through a passive external circuit. This convention remains independent of the carrier type.

Electron discovery explained why electron drift in metals is opposite to conventional current. In electrolytes and semiconductors, several positive and negative carrier types can contribute, so current should not be defined only as electron motion.

Who Invented DC Current?

No single person invented direct current. Alessandro Volta’s pile, announced in 1800, provided an early continuous source that enabled sustained-current experiments. Current direction was later standardised as a sign convention.

In the late nineteenth century, companies associated with Thomas Edison and George Westinghouse competed over incompatible DC and AC distribution systems. Nikola Tesla’s polyphase motor patents supported Westinghouse’s AC system.

Edison’s companies developed low-voltage DC lighting networks, including the Pearl Street station in New York. Their short distribution range required generating stations near customers.

The commercial rivalry was primarily between Edison and Westinghouse interests, not a personal contest between Edison and Tesla. Westinghouse supplied the polyphase AC generating system at Niagara Falls, with contributions from several engineers. AC became dominant because transformers made high-voltage transmission and lower-voltage distribution practical.

Modern power electronics make efficient conversion between AC and DC possible, so today’s systems commonly use both.