Voltage Regulators: Linear, Shunt, and Zener Diode

💡
Key learnings:
  • Voltage Regulator Definition: A voltage regulator is defined as a device that keeps the voltage level within suitable limits to protect connected equipment.
  • Linear Voltage Regulator: This type adjusts resistance to maintain a steady output voltage and includes series and shunt types.
  • Shunt Voltage Regulator: A shunt voltage regulator diverts excess current to the ground, ensuring stable voltage across the load.
  • Zener Diode as Voltage Regulator: Zener diodes provide a reference voltage and are used in series and shunt voltage regulators.
  • Switching Voltage Regulator: These regulators switch on and off quickly to control voltage efficiently, allowing for step-up, step-down, and inverting outputs.

What is Voltage Regulation

A voltage regulator is an electronic device that keeps the power supply voltage within safe limits. The connected equipment must handle the voltage value. The voltage source should be within a range acceptable for the equipment, which is managed by a voltage regulator.

A voltage regulator controls the voltage level, no matter the changes in input voltage or load. It protects devices from damage and can regulate both AC and DC voltages, depending on its design.

What is Voltage Regulation

Types of Voltage Regulators

There are two main types of voltage regulators available:

  • Linear Voltage Regulators
  • Switching Voltage Regulators

These can be further classified into more specific voltage regulators, as discussed below.

Linear Voltage Regulator

This type of voltage regulator acts as a voltage divider using FET in the Ohmic region. It maintains a steady output by varying resistance according to the load. There are two main types of linear voltage regulators:

  • Series voltage regulator
  • Shunt voltage regulator

Series Voltage Regulator

It implements a variable element positioned in series with the connected load. The steady output is sustained by varying the resistance of this element with respect to the load. They are of two types that are briefed below.

Discrete Transistor Series Voltage Regulator

In the block diagram, an unregulated input first goes to a controller that adjusts the input voltage. This regulated output is sent to a feedback circuit, sampled by a sampling circuit, and compared with a reference voltage in the comparator before being sent back to the output.

Series Voltage Regulator

The comparator circuit sends a control signal to the controller if the output voltage changes. The controller then adjusts the voltage to keep it within the acceptable range, ensuring a stable output.

Zener Diode as Voltage Regulator

When a Zener diode is used as a voltage regulator, it is known as a Zener controlled transistor series voltage regulator or an emitter follower voltage regulator. Here, the transistor used is emitter follower (see figure below). The emitter and the collector terminals of the series pass transistor used here are in series with respect to load. The variable element is a transistor and the Zener diode will supply the reference voltage.

Zener Diode Voltage Regulator Formula
Zener Diode as Voltage Regulator

Shunt Voltage Regulator

The shunt voltage regulator provides a way from the supply voltage reaching to the ground with the help of variable resistance. From the load, the current is shunted away from the load to the ground. We can simply say that this regulator can absorb current and it is less efficient compared to the series voltage regulator. The applications include error amplifiers, voltage monitoring, precision current limiters, etc. They are of two types that are briefed below.

Discrete Transistor Shunt Voltage Regulator

Here, the current is shunted away from the load. The controller will shunt a portion of the total current that is developed by the unregulated input which is given to the load. The voltage regulation takes place across the load.

Here, the comparator circuit will give a control signal to the controller whenever there is an increase or decrease in the output voltage because of the variation in load. Thus, the controller will shunt the extra current from the load so as to get a sustained voltage as the output.

Shunt Voltage Regulator

Zener Controlled Transistor Shunt Voltage Regulator

Here, the unregulated voltage is directly proportional to the voltage drop occurs in the series resistance. This voltage drop is related to the current given to the load. The output voltage is related to the transistor base emitter voltage (VBE) and the Zener diode.

Zener Diode Shunt Regulator
Zener Diode Voltage Regulator Circuit Diagram
Advantages of Linear Voltage RegulatorDisadvantages of Linear Voltage Regulator
Design is very simpleLow efficiency
Less output rippleSpace requirement is large
Response time is fastVoltage cannot be increased
Less noiseA heat sink is sometimes required

Switching Voltage Regulator

This regulator quickly switches a device in series to on and off. Like the linear regulators, a feedback mechanism is incorporated here to control the quantity of charge carried to the load. This quantity is set as the duty cycle of the switch. The output voltage can be greater or the polarity of output can be opposite that of the input by using this voltage regulator.

This is a highly efficient voltage regulator. Three different types are step-up voltage regulator, buck voltage regulator, and boost/buck voltage regulator. The most simplified circuit diagram of a switching voltage regulator is shown below.

switching voltage regulator
Advantages of Switching Voltage RegulatorDisadvantages of Switching Voltage Regulator
Efficiency is very high.Complex design
Size and weight are very low.Expensive
Boost or buck or inverting or buck/boost is possible.Noise is high
Less noiseTransient recovery time is time-consuming

Application of Voltage Regulators

The applications for voltage regulators include:

  • Power distribution system
  • Automobile alternator
  • Power station generator plant
  • Computer power supplies
Want To Learn Faster? 🎓
Get electrical articles delivered to your inbox every week.
No credit card required—it’s 100% free.

About Electrical4U

Electrical4U is dedicated to the teaching and sharing of all things related to electrical and electronics engineering.

Leave a Comment