Thermoelectric Generators: Principles, Materials and Applications

💡
Key learnings:
  • Thermoelectric Generator Definition: A thermoelectric generator (TEG) is a device that converts heat energy into electrical energy using the Seebeck effect, which occurs when there is a temperature difference between two different conductors.
  • Working Principle: TEGs work by creating a temperature difference across a thermoelectric module, generating an electric current that can power an external load or charge a battery
  • Common Materials: Common thermoelectric materials include bismuth telluride for low temperatures, lead telluride for medium temperatures, and skutterudites for high temperatures.
  • Applications: TEGs are used for power generation from waste heat, cooling electronic devices, and powering remote devices with radioisotopes or solar heat.
  • Challenges and Future Directions: TEGs face challenges like low efficiency and high cost, but future research aims to find new materials and develop advanced systems to improve performance.

A thermoelectric generator (TEG) converts heat energy into electrical energy through the Seebeck effect: when a temperature difference exists between two different conductors or a circuit of them, an electric potential difference appears. TEGs are solid-state: no moving parts, silent operation and reliability over long periods. They harvest waste heat from industrial processes, vehicles, power plants and even human bodies, and they power remote devices such as sensors, wireless transmitters and spacecraft from radioisotope or solar heat.

How Does a Thermoelectric Generator Work?

A thermoelectric generator consists of two main components: thermoelectric materials and thermoelectric modules.

Thermoelectric Power Generator

Thermoelectric materials show the Seebeck effect, generating an electric voltage when a temperature difference exists. One flavour, n-type, carries extra electrons; the other, p-type, carries a deficit of them. Connected in series with metal electrodes, these materials form a thermocouple, the basic unit of a thermoelectric generator.

A thermoelectric module is a device that contains many thermocouples connected electrically in series and thermally in parallel. A thermoelectric module has two sides: a hot side and a cold side. When the hot side is exposed to a heat source and the cold side is exposed to a heat sink, a temperature difference is created across the module, causing a current to flow through the circuit. The current can be used to power an external load or charge a battery. The voltage and power output of a thermoelectric module depend on the number of thermocouples, the temperature difference, the Seebeck coefficient and the electrical and thermal resistances of the materials.

The efficiency of a thermoelectric generator is defined as the ratio of electrical power output to heat input. This efficiency is limited by the Carnot efficiency, the maximum possible efficiency for any heat engine between two temperatures. The Carnot efficiency is given by:

ηCarnot = 1 − Tc/Th

Seebeck Power Generation Equation 1

where Tc is the cold-side temperature and Th is the hot-side temperature.

The actual efficiency of a thermoelectric generator is much lower than the Carnot efficiency due to various losses such as Joule heating, thermal conduction, and thermal radiation. The actual efficiency of a thermoelectric generator depends on the figure of merit (ZT) of the thermoelectric materials, which is a dimensionless parameter that measures the performance of a material for thermoelectric applications. The figure of merit is given by:

ZT = α²σT/κ

Seebeck Power Generation Equation 2

where α is the Seebeck coefficient, σ is the electrical conductivity, κ is the thermal conductivity, and T is the absolute temperature.

The higher the figure of merit, the higher the efficiency of the thermoelectric generator. The figure of merit depends on both intrinsic properties (such as electron and phonon transport) and extrinsic properties (such as doping level and geometry) of the materials. The goal of thermoelectric materials research is to find or design materials that have a high Seebeck coefficient, high electrical conductivity and low thermal conductivity, which are often conflicting requirements.

What are Some Common Thermoelectric Materials?

Thermoelectric materials fall into three categories: metals, semiconductors and complex compounds.

Metals have high electrical conductivity but low Seebeck coefficient and high thermal conductivity, resulting in a low figure of merit. Metals are mainly used as electrodes or interconnects in thermoelectric modules.

Semiconductors balance electrical conductivity and Seebeck coefficient usefully, and doping tunes their carrier type and concentration. That balance yields a workable figure of merit, and semiconductors are the standard thermoelectric materials for low-temperature applications (below 200°C).

Complex compounds pair a high Seebeck coefficient and low thermal conductivity with still-usable electrical conductivity, which lifts their figure of merit. Multiple elements with different valence states and crystal structures create complex band structures and strong phonon scattering, both of which help performance. High-temperature applications (above 200°C) rely on them heavily.

Some examples of common thermoelectric materials are:

  • Bismuth telluride (Bi2Te3) and its alloys: These are the most widely used thermoelectric materials for low-temperature applications (below 200°C), such as cooling devices and power generation from waste heat sources. Bi2Te3 has a layered structure that consists of alternating quintuple layers of Bi2 and Te3 atoms bonded by weak van der Waals forces. This structure results in low thermal conductivity due to phonon scattering at the layer boundaries. Bi2Te3 can be alloyed with other elements such as antimony (Sb), selenium (Se), or sulfur (S) to tune its electrical properties and optimize its figure of merit.
  • Lead telluride (PbTe) and its alloys: These are among the most widely used thermoelectric materials for medium-temperature applications (200-600°C), such as power generation from automotive exhaust or industrial waste heat sources. PbTe has a rock-salt structure that consists of alternating layers of Pb2+ and Te2- ions bonded by strong ionic forces. This structure results in a high Seebeck coefficient due to heavy Pb atoms that create large band degeneracy near the Fermi level. PbTe can be alloyed with other elements such as tin (Sn), thallium (Tl), or sodium (Na) to raise its figure of merit.
  • Skutterudites: These are complex compounds with the general formula MX3, where M is a transition metal (such as cobalt, Co) and X is a pnictogen (such as antimony, Sb).
  • Seebeck Power Generation Equation 3
  • Skutterudites have a cubic structure that consists of a three-dimensional network of M4X12 units with large voids that can accommodate guest atoms (such as rare earth elements, RE). The guest atoms act as phonon scatterers that reduce the thermal conductivity, while the host atoms provide high electrical conductivity and Seebeck coefficient. Skutterudites are promising thermoelectric materials for medium- to high-temperature applications (300-800°C), such as power generation from waste heat recovery or concentrated solar power.
  • Half-Heusler compounds: These are ternary compounds with the general formula XYZ, where X is a transition metal (such as titanium, Ti), Y is another transition metal (such as nickel, Ni), and Z is a main group element (such as tin, Sn).
  • Seebeck Power Generation Equation 4
  • Half-Heusler compounds have a cubic structure that consists of four interpenetrating fcc sublattices, one occupied by X atoms and the other three occupied by Y and Z atoms in a 1:2 ratio. Half-Heusler compounds have high Seebeck coefficient and electrical conductivity due to their complex electronic band structures and low thermal conductivity due to their heavy constituent atoms. Half-Heusler compounds are promising thermoelectric materials for high-temperature service (several hundred degrees Celsius), such as power generation from nuclear reactors or aerospace engines.

What are Some Applications of Thermoelectric Generators?

Thermoelectric generators have various applications in different fields, depending on the temperature range, power output and heat source availability. Some examples of thermoelectric generator applications are:

  • Cooling devices: Thermoelectric generators can be used to cool electronic components such as microprocessors, lasers and sensors by applying an electric current to create a temperature difference between the hot and cold sides of the module. This process is called thermoelectric cooling or the Peltier effect, which is the reverse of the Seebeck effect. Thermoelectric cooling devices have advantages over conventional cooling methods, such as compactness, reliability, noiselessness and precise temperature control.
  • Power generation from waste heat: Thermoelectric generators can be used to harvest waste heat from various sources, such as industrial processes, automobiles, power plants and even human body heat, and convert it into useful electricity. This can improve energy efficiency and reduce the greenhouse gas emissions of these sources. For example, thermoelectric generators can be integrated into automotive exhaust systems to recover some of the heat lost during combustion and generate electricity for onboard electronics or battery charging. Thermoelectric generators can also be attached to human skin or clothing to generate electricity from body heat for powering wearable devices or medical implants.
  • Power generation from radioisotopes: Thermoelectric generators power remote devices such as sensors, wireless transmitters and spacecraft from radioisotope heat sources.
  • Seebeck Power Generation Equation 5
  • Radioisotopes are unstable isotopes that emit radiation and decay into other elements. The radiation can be converted into heat by using a material that absorbs it, such as lead or tungsten. The heat can then be converted into electricity by using thermoelectric modules. Radioisotope thermoelectric generators (RTGs) have advantages over other power sources, such as batteries or solar panels, in terms of long lifetime, high reliability and independence from environmental conditions. RTGs have been used to power many space missions, such as Voyager 1 and 2, Curiosity rover, and Perseverance rover.

What are Some Challenges and Future Directions for Thermoelectric Generators?

TEGs offer many benefits for energy conversion and harvesting, but they face challenges that must be addressed for practical use. These challenges include:

  • Low efficiency: The efficiency of thermoelectric generators is limited by the Carnot efficiency and the figure of merit of the thermoelectric materials. The current state-of-the-art thermoelectric materials have a figure of merit around 1-2 at room temperature and 2-3 at high temperature, resulting in an efficiency of 5-10% at best. To achieve higher efficiency, new thermoelectric materials with a higher figure of merit need to be discovered or designed by using advanced techniques such as band structure engineering, nanostructuring, doping, alloying or heterostructures.
  • High cost: The cost of thermoelectric generators is mainly determined by the cost of the thermoelectric materials and modules. Current thermoelectric materials are often composed of rare or toxic elements that are expensive or difficult to obtain. The fabrication of thermoelectric modules also requires sophisticated processes and equipment that increase the cost. To reduce the cost of thermoelectric generators, alternative materials that are abundant, cheap and environmentally friendly need to be developed or discovered. The fabrication of thermoelectric modules also needs to be simplified and scaled up to reduce the manufacturing cost and increase the production rate.
  • Thermal management: The performance of thermoelectric generators depends on the temperature difference between the hot and cold sides of the module. Therefore, efficient heat transfer and dissipation are what make high power output and reliability possible. The heat source and the heat sink need to be properly designed and matched with the thermoelectric module to ensure optimal heat flow and temperature distribution. The thermal contact resistance between the module and the heat source or sink also needs to be minimized to reduce thermal losses. The thermoelectric materials and modules also need to withstand high temperatures and thermal stresses without degradation or failure.
  • System integration: Thermoelectric generators are not standalone devices but rather components of a larger system that includes other elements, such as heat exchangers, electrical converters, controllers, sensors and batteries. The integration of these elements into a coherent and functional system requires careful design and optimization of various parameters, such as electrical impedance, voltage regulation, power conditioning, load matching and system control. The system integration also needs to consider the specific application requirements, such as size, weight, cost, durability, safety and environmental impact.

The future directions for thermoelectric generator research and development include:

  • Novel thermoelectric materials: Efficiency gains start with materials whose figure of merit beats today’s best. Band structure engineering, nanostructuring, doping, alloying and heterostructures all manipulate electronic and phononic behaviour toward that goal, and entirely new classes such as organic, hybrid or topological materials may show unconventional thermoelectric effects.
  • Advanced thermoelectric modules: Better modules come from three directions: higher-figure-of-merit materials, architectures that raise power output or cut thermal losses, and fabrication methods that lower cost while raising quality.
  • Innovative thermoelectric systems: System-level design matters as much as the module. New heat sources or sinks that hold a strong temperature difference, integration schemes that optimise performance and fresh application domains all extend where thermoelectric generators make sense.

Conclusion

Thermoelectric generators turn heat directly into electricity with no moving parts, no noise and little maintenance, which makes them attractive wherever waste heat, radioisotopes or solar heat would otherwise go unused. Low efficiency and high cost still hold them back, and progress depends on materials with a higher figure of merit, better modules and smarter system integration. Each research front feeds the others, and together they decide how large a role thermoelectric generators play in future energy conversion.

Want To Learn Faster? 🎓
Get electrical articles delivered to your inbox every week.
No credit card required—it’s 100% free.

About Electrical4U

Electrical4U is dedicated to the teaching and sharing of all things related to electrical and electronics engineering.