MOSFET as a Switch

💡
Key learnings:
  • MOSFET Definition: A MOSFET is defined as a type of transistor used to amplify or switch electronic signals, operating mainly in cut-off, linear, and saturation regions.
  • Switching Action: Using MOSFET as a switch involves changing its state from non-conducting to conducting, controlled by the gate voltage relative to a threshold.
  • Circuit Example: In practical circuits, the output voltage of a MOSFET switch alternates between high and zero, contingent upon the gate voltage exceeding a certain threshold.
  • Types of MOSFETs: Both n-channel and p-channel MOSFETs can be configured to act as switches, each requiring specific voltage conditions to operate.
  • Efficiency and Speed: MOSFETs offer higher switching rates and better performance in electronic circuits compared to bipolar junction transistors (BJTs).

MOSFETs have three operating regions: cut-off, linear or ohmic, and saturation. For analog gain they are biased in saturation, where drain current is set by the gate and stays almost flat as drain voltage changes. For switching, MOSFETs are driven between cut-off and the ohmic region. Cut-off stops current (open switch). The ohmic region gives a small drain-source drop at high current (closed switch). That is faster than a typical bipolar junction transistors switch.

Figure 1 shows a simple circuit which uses an n-channel enhancement MOSFET as a switch. Here the drain terminal (D) of the MOSFET is connected to the supply voltage VS via the drain resistor RD while its source terminal (S) is grounded. Further, it has an input voltage Vi applied at its gate terminal (G) while the output Vo is drawn from its drain.
n channel enhancementtype mosfet functioning as a switch

Now consider the case where Vi applied is 0V, which means the gate terminal of the MOSFETis left unbiased. As a result, the MOSFET will be OFF and operates in its cutoff region wherein it offers a high impedance path to the flow of current which makes the IDS almost equivalent to zero. As a result, even the voltage drop across RD will become zero due to which the output voltage Vo will become almost equal to VS.
Next, consider the case where the input voltage Vi applied is greater than the threshold voltage VT of the device. Under this condition, the MOSFET will start to conduct and if the VS provided is greater than the pinch-off voltage VP of the device (usually it will be so), then the MOSFET is driven into its ohmic (linear) region. This further means that the device will offer low resistance path for the flow of constant IDS, almost acting like a short circuit. As a result, the output voltage will be pulled towards low voltage level, which will be ideally zero.

From the discussion presented, it is evident that the output voltage alters between VS and zero depending on whether the input provided is less than or greater than VT, respectively. Thus MOSFETs can work as electronic switches when they are driven between cut-off and the ohmic region.
Similar to the case of n-channel enhancement type MOSFET, even n-channel depletion type MOSFETs can be used to perform switching action as shown by Figure 2. The behaviour of such a circuit is seen to be almost identical to that explained above except the fact that for cut-off, the gate voltage VG needs to be made negative and should be lesser than -VT.

n-channel depletion-type mosfet functioning as a switch
Next, Figure 3 shows the case wherein the p-channel enhancement MOSFET is used as a switch. Here it is seen that the supply voltage VS is applied at its source terminal (S) and the gate terminal is provided with the input voltage Vi while the drain terminal is grounded via the resistor RD. Further the output of the circuit Vo is obtained across RD, from the drain terminal of the MOSFET.
In the case of p-type devices the conduction current will be due to holes and will thus flow from source to drain ISD, and not from drain to source (IDS) as in the case of n-type devices. Now, let us assume that the input voltage which is nothing but the gate voltage VG of the MOSFET goes low. This causes the MOSFET to switch ON and to offer a low (almost negligible) resistance path to the current flow. As a result heavy current flows through the device which results in a large voltage drop across the resistor RD. This inturn results in the output which is almost equal to the supply voltage VS.
p channel enhancement type mosfet functioning as a switch
Next, consider the case where Vi goes high i.e. when Vi will be greater than the threshold voltage of the device (VT will be negative for these devices). Under this condition, the MOSFET will be OFF and offers a high impedance path for the current flow. This results in almost zero current leading to almost zero voltage at the output terminal.

Similar to this, even p-channel depletion-type MOSFETs can be used to perform switching action as shown by Figure 4. The working of this circuit is almost similar to the one explained above except for the fact that here the cut-off region is experienced only if Vi = VG is made positive such that it exceeds the threshold voltage of the device.
p channel depletion type mosfet functioning as a switch
The table presented below summarizes the discussion presented above.
mosfet table