Electric Lines of Force

💡
Key learnings:
  • Definition of Electric Lines of Force: Definition of Electric Lines of Force
  • Creation: Electric lines of force are created by placing a unit positive charge in the electric field of another charge.
  • Direction: The direction of electric lines of force is shown with arrowheads indicating the path of the positive charge.
  • Interaction Between Charges: A unit positive charge moves towards negative charges and away from positive charges, creating curved paths in combined fields.
  • Properties: Electric lines of force start from positive charges and end at negative charges, never cross, and indicate the electric field’s direction with tangents.
If a free to move unit positive charge is placed in an electric field, it will experience a force due to which the unit positive charge will move along a particular path. The unit positive charge can be placed at different positions in the field and the unit positive charge will follow different paths when it is placed in different positions. The paths, along which the unit positive charge will move due to electrostatic force in the field are called electric lines of force.

The direction of electric lines of force follows the movement of a unit positive charge in the field. Arrowheads represent this direction.

Let us take a negative charge of – Q coulomb. Also, let us place a unit positive charge at a point in the field of charge – Q.

According to Coulomb’s law, the unit positive charge will experience an attraction force towards the center of the said negative charge.

If the unit positive charge is free to move, it will move towards the charge – Q along the straight line joining the center of the unit positive charge and the center of the said negative charge.

The line along which the unit positive charge moves towards the said negative charge is defined as an electric line of force. If we place the unit positive charge anywhere else in the field, a new line of force is created through that point.

Now, let us take a positive charge of + Q coulomb. We place a unit positive charge at a point in the field.

According to Coulomb’s law, the unit positive charge will experience a repulsive force.

As the unit positive charge is free to move, it will move away along the straight line joining the center of the unit positive charge and the said positive charge. The line along which the unit positive charge moves away from the said positive charge is an electric line of force. Similarly, if we place the unit positive charge anywhere else in the field, a new line of force is created through that point.

Since we can place a unit positive charge at an infinite number of points in the electric field, theoretically there will be an infinite number of lines of force created in the field of an electric charge. But mathematically, by convention, to represent the influence of the electric charge in the field, the total number of lines of force emanated from an electric charge is taken as equal to the value of the electric charge measured in coulombs. That means a Q Coulomb charge emanates Q number of lines of force surrounding it.



Now, let us place one positively charged object of + Q Coulomb and one negatively charged object of – Q Coulomb side by side as shown below. Let us place a unit positive charge at any point in between these two charged objects. The unit positive charge will experience an attraction force from the negatively charged object and a repulsion force from the positively charged object. Under this combined attraction and repulsion, the unit positive charge will move along a curved line from the center of the + Q charged object to the center of the – Q charged object. Considering the other lines of force, we can draw the electric field like below.

Now, let us place two positively charged objects of + Q Coulomb side by side as shown below. Let us place a unit positive charge at any point on one of the charged objects. The unit positive charge will experience a repulsion force from the + Q charge on which it is placed. It also experiences another repulsive force from the nearby + Q charge. Under these two repulsion forces from both sides, the unit positive charge will move away from both + Q charges, as shown below. Considering the other lines of force, we can draw the electric field like below.

Properties of Electric Lines of Force

  1. Each electric line of force is conceptually imagined; it has no physical existence.
  2. The total number of lines of force emanated from a charged body is equal, by convention, to the charge of the body measured in Coulombs.
  3. Each electric line of force originates from a positive charge and terminates on a negative charge.
  4. A tangent drawn at any point on an electric line of force indicates the direction of the electric field at that point.
  5. Each electric line of force emanates normally from the surface of the charged body.
  6. Electric lines of force can only contract longitudinally.
  7. Electric lines of force can expand laterally.
  8. No two electric lines of force cross each other.
  9. Electric lines of force in the same direction repel each other.
  10. Electric lines of force in opposite directions attract each other.
  11. No lines of force can exist inside a conductor.