Nickel Iron Battery or Edison Battery Working and Characteristics

What Is A Nickel Iron Battery

A nickel-iron battery uses a rechargeable alkaline chemistry with nickel oxyhydroxide positive material and an iron negative electrode. The names Nickel Iron Battery and Edison Battery refer to this system. A Ni-Fe battery is mechanically rugged and can tolerate some electrical abuse, but it is not short-circuit proof and still requires correctly rated protection, charging … Read more

Fan Out of Logic Gates

What Is The Fan Out Of Logic Gates

Fan-out in digital electronics is the number of same-family gate inputs that one logic-gate output can drive without leaving the valid logic levels. One output can feed several inputs, but only up to that count.The limit is set by how much current the output can source at a high level and how much current it … Read more

Error Detection and Correction Codes

What Are Error Detection And Correction Codes

Error detection and correction codes add extra bits so a receiver can see whether a digital word was changed in transit, and in some codes restore the original bits. Analog and digital links both pick up errors; a computer or a comms link needs a definite check because one wrong bit can change a code. … Read more

Motor Thermal Overload Protection

What Is Motor Thermal Overload Protection

Motor thermal overload protection must allow normal starting current but disconnect an induction motor before sustained heating damages its insulation. The principle of three phase induction motor explains why current is high at start. A balanced three phase power supply applied to the stator windings creates a rotating magnetic field at synchronous speed. Conductive rotor … Read more

Armature Reaction in DC Machine

What Is Armature Reaction In Dc Machine

Armature reaction is the armature mmf acting on the main field. At no load the magnetic neutral axis sits on the geometrical neutral axis, so the brushes sit there too. On load the armature flux lies along the interpolar axis and looks roughly triangular. That brush-axis mmf cross-magnetizes the main field. Flux crowds at the … Read more

Signal Generator: What are They? Circuit & Block Diagram

What Is A Signal Generator

What is a Signal Generator? Signal generators provide controlled electrical stimuli for design, verification, repair and troubleshooting. Depending on the instrument, the output may be periodic, pulsed, modulated, patterned or an arbitrary stored waveform. Typical settings include frequency, amplitude, DC offset, phase, duty cycle, sweep, burst and modulation. A generator supplies the stimulus; an oscilloscope, … Read more

Digital Frequency Meter

What Is A Digital Frequency Meter

A digital frequency meter, also called a frequency counter, measures the repetition rate of a periodic electrical signal and displays the result in hertz. A direct counter counts input cycles or pulse edges during a precisely timed gate interval. It then divides that count by the gate time. The number of displayed digits is not … Read more

Basic Signal Operations

What Are The Basic Signal Operations

A signal is a function that represents information or a measurable quantity. Its independent variable can be time, position or another index. A system can receive signals as inputs and produce signals as outputs.The following basic signal operations transform signal values or the independent-variable axis. Each definition uses a continuous-time signal x(t); the corresponding discrete-time … Read more

Oscillator Transducer: What is it? (Advantages & Disadvantages)

What Is An Oscillator Transducer

What Is an Oscillator Transducer? An oscillator transducer is a type of transducer in which a measured quantity changes an oscillator’s frequency. Force, pressure or displacement can move a mechanical element that changes capacitance or inductance. The system then measures frequency and uses a calibration relationship to recover the input quantity. It does not inherently … Read more

Quantum Numbers

Quantum numbers label the allowed quantum states of electrons in an atom. They describe an orbital’s shell, angular momentum and angular-momentum projection, together with an electron’s spin projection. They do not specify a fixed position or classical path. Electron configurations use four quantum numbers: Principal Quantum Number (n) The principal quantum number, n, labels the … Read more