Annealing Test for Wires and Conductors

What Is The Annealing Test For Wires And Conductors

The annealing test measures elongation at break of annealed copper wires, aluminium welding-cable wires and solid conductors of electric power cables. A current-carrying core of a power cable is twisted and bent during laying, so the metal must stretch without cracking. IS 10810-1 pulls a marked length to fracture and IS 8130 requires that elongation … Read more

Tensile Test of Conductors

What Is The Tensile Test Of Conductors

The tensile test measures breaking strength of aluminium wires used in electric power cables. IS 10810-2 pulls a specimen to fracture so the conductor grade can be checked against IS 8130. The metal must survive pulling during stranding and laying. Soft copper uses the annealing (elongation) test instead. Apparatus required for Tensile Test Method of … Read more

Test for Thickness of Insulation of Power Cable

What Is Test For Thickness Of Insulation Of Power Cable

This test measures insulation and sheath thickness on electric power cables. IS 10810-6 is the Indian method. A power cable needs enough wall to stand the rated voltage and the pull of laying. The product standard then compares the measured average and the measured minimum with its own limits. Apparatus required to test for thickness … Read more

H Parameters (Hybrid Parameters) in Two Port Networks

What are H Parameters (Hybrid Parameters)? H parameters (hybrid parameters) use Z parameters, Y parameters, voltage ratios, and current ratios to show the relationship between voltage and current in a two port network. They are useful for describing input-output characteristics, especially when Z or Y parameters are hard to measure, as in a transistor. H … Read more

Mobility of Charge Carrier

Mobility Of Electrons

Mobility of a charge carrier is the ratio of drift velocity to the applied electric field in a conductor. Drift velocity is set by that field and by the metal’s mobility of charge carriers. Different metals therefore have different drift speeds in the same field.In a metal the valence band is not completely filled, so … Read more

Conductivity of Semiconductor

What Is The Conductivity Of Semiconductor

Conductivity of a semiconductor is set by how many free carriers it has. Metals (conductors) have a high free-electron density and therefore a high conductance (and a low resistance). Insulators have very few free electrons. A semiconductor sits between those two densities, so its conductivity sits between a metal and an insulator. That is why … Read more

Donor and Acceptor Impurities in Semiconductor

What Are Donor And Acceptor Impurities In Semiconductor

A small amount of impurity to a semiconductor contributes free electrons or holes and so changes how the semiconductor conducts. That process is doping. A pentavalent donor (atoms with five valence electrons) replaces a host atom. Four valence electrons form bonds with neighbours. The fifth electron is only weakly bound and can become a free … Read more

Electron volt or eV

What Is Electron Volt

An electron volt is the energy one electron gains when it moves through 1 volt. Start from ordinary circuit power: the watt.W = VI, where V is the voltage and I is the current.Current (I) is charge per unit time, so instantaneous power is: Here q(t) is the charge transferred in time t. Energy then … Read more

Current Density in Metal and Semiconductor

What Is The Current Density In Metal And Semiconductor

Current density is the current through a unit area of a conductor. That quantity is used throughout electrical engineering. Current Density in Metal Imagine a conductor with a cross-section of 2.5 square mm. If an electric potential causes a current of 3 A, the current density is 1.2 A/mm² (3/2.5). This assumes the current is … Read more