- Alphanumeric Codes Definition: Alphanumeric codes are binary systems used to represent letters, numbers, and symbols in a format that computers can understand.
- ASCII: A 7-bit code that encodes 128 unique symbols, illustrating basic English characters and control codes.
- EBCDIC Usage: Developed by IBM, EBCDIC is an 8-bit code used primarily in older IBM computers, encoding 256 distinct characters.
- UNICODE Advantages: Unicode supports over a million unique characters, making it essential for global digital communication across various platforms and devices.
- Evolution of Codes: Starting from Hollerith code to modern Unicode, alphanumeric codes have significantly evolved to meet the expanding needs of global data interchange.
What is Alphanumeric Code?
Alphanumeric codes are character-encoding conventions that represent letters, numbers and other text elements as numeric values. Computers store and transmit those values as binary data. The term character code is broader because it also covers punctuation, control functions and symbols.
A keyboard sends key events or scan codes, and software interprets them as text according to the active layout and character encoding. A display then renders glyphs for the decoded characters. Mouse input describes actions and positions rather than encoded text.
Hollerith-derived punched-card systems were an early form of machine-readable data. A later IBM card had 80 columns and 12 row positions, with a pattern of holes in a column representing a character. Calling this simply a 12-bit code hides the physical card format and the different coding conventions used over time.
Punched cards once carried data and program instructions into tabulating machines and computers. They are now a legacy storage medium, while software systems use electronic character encodings for text interchange.
The sections below compare ASCII, the EBCDIC code-page family and Unicode. ASCII remains an important 7-bit foundation, EBCDIC remains in use on some IBM systems, and Unicode supplies the common character repertoire used by modern encoding forms such as UTF-8.
ASCII Code
ASCII code stands for American Standard Code for Information Interchange. It is a 7-bit coded character set for English letters, decimal digits, punctuation and control functions.
Seven bits provide 128 values, numbered 0 to 127. The excerpt below lists values 0 to 15. Its BIN column pads each 7-bit ASCII value with a leading zero so that the entries appear as full 8-bit bytes.
| DEC | OCT | HEX | BIN | Symbol | Description |
| 0 | 000 | 00 | 00000000 | NUL | Null char |
| 1 | 001 | 01 | 00000001 | SOH | Start of Heading |
| 2 | 002 | 02 | 00000010 | STX | Start of Text |
| 3 | 003 | 03 | 00000011 | ETX | End of Text |
| 4 | 004 | 04 | 00000100 | EOT | End of Transmission |
| 5 | 005 | 05 | 00000101 | ENQ | Enquiry |
| 6 | 006 | 06 | 00000110 | ACK | Acknowledgment |
| 7 | 007 | 07 | 00000111 | BEL | Bell |
| 8 | 010 | 08 | 00001000 | BS | Back Space |
| 9 | 011 | 09 | 00001001 | HT | Horizontal Tab |
| 10 | 012 | 0A | 00001010 | LF | Line Feed |
| 11 | 013 | 0B | 00001011 | VT | Vertical Tab |
| 12 | 014 | 0C | 00001100 | FF | Form Feed |
| 13 | 015 | 0D | 00001101 | CR | Carriage Return |
| 14 | 016 | 0E | 00001110 | SO | Shift Out / X-On |
| 15 | 017 | 0F | 00001111 | SI | Shift In / X-O |
This excerpt contains only the first 16 ASCII control values. In its final two rows, SO means Shift Out and SI means Shift In; XON is the separate DC1 control at decimal 17. The full set also includes the remaining control values, space, punctuation, digits, uppercase and lowercase English letters plus DEL.
EBCDIC Code
EBCDIC stands for Extended Binary Coded Decimal Interchange Code. IBM developed it in 1963, and EBCDIC code pages remain in use on systems including IBM zSystems and iSeries. A single-byte EBCDIC code page has 256 possible byte values, but EBCDIC is a family of code pages rather than one universal character map. Letters and digits are invariant across common pages, while some punctuation and national characters vary. The table below shows selected invariant values from EBCDIC code.
| Char | EBCDIC | HEX | Char | EBCDIC | HEX | Char | EBCDIC | HEX |
| A | 1100 0001 | C1 | P | 1101 0111 | D7 | 4 | 1111 0100 | F4 |
| B | 1100 0010 | C2 | Q | 1101 1000 | D8 | 5 | 1111 0101 | F5 |
| C | 1100 0011 | C3 | R | 1101 1001 | D9 | 6 | 1111 0110 | F6 |
| D | 1100 0100 | C4 | S | 1110 0010 | E2 | 7 | 1111 0111 | F7 |
| E | 1100 0101 | C5 | T | 1110 0011 | E3 | 8 | 1111 1000 | F8 |
| F | 1100 0110 | C6 | U | 1110 0100 | E4 | 9 | 1111 1001 | F9 |
| G | 1100 0111 | C7 | V | 1110 0101 | E5 | blank | … | … |
| H | 1100 1000 | C8 | W | 1110 0110 | E6 | . | … | … |
| I | 1100 1001 | C9 | X | 1110 0111 | E7 | ( | … | … |
| J | 1101 0001 | D1 | Y | 1110 1000 | E8 | + | … | … |
| K | 1101 0010 | D2 | Z | 1110 1001 | E9 | $ | … | … |
| L | 1101 0011 | D3 | 0 | 1111 0000 | F0 | * | … | … |
| M | 1101 0100 | D4 | 1 | 1111 0001 | F1 | ) | … | … |
| N | 1101 0101 | D5 | 2 | 1111 0010 | F2 | – | … | … |
| O | 1101 0110 | D6 | 3 | 1111 0011 | F3 | / |
Unicode
Unicode assigns each encoded character a code point in a shared code space from U+0000 to U+10FFFF. The code space contains 1,114,112 code points, although not every point is assigned to a character. In Unicode 17.0, 159,801 characters are assigned. UTF-8, UTF-16 and UTF-32 encode the same code points with different code-unit sequences, so a code point is not the same as a stored byte or a displayed glyph. The table below is a legacy illustration, not an authoritative chart. In particular, its 0080 row shows Windows-1252-style printable mappings, but Unicode assigns U+0080 to U+009F as C1 control code points. Use the Unicode Consortium’s current code charts for exact assignments.
| 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 0A | 0B | 0C | 0D | 0E | 0F | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 1A | 1B | 1C | 1D | 1E | 1F | ||
| 0000 | ‑ | | Symbols | ||||||||||||||||||||||||||||||
| 0020 | ! | “ | # | $ | % | & | ‘ | ( | ) | * | + | , | – | . | / | 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | : | ; | < | = | > | ? | Number | |
| 0040 | @ | A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | [ | \ | ] | ^ | _ | Alphabet |
| 0060 | ` | a | b | c | d | e | f | g | h | i | j | k | l | m | n | o | p | q | r | s | t | u | v | w | x | y | z | { | | | } | ~ | | |
| 0080 | € | | ‚ | ƒ | „ | … | † | ‡ | ˆ | ‰ | Š | ‹ | Œ | | Ž | | | ‘ | ’ | “ | ” | • | – | — | ˜ | ™ | š | › | œ | | ž | Ÿ | |
| 00A0 | ¡ | ¢ | £ | ¤ | ¥ | ¦ | § | ¨ | © | ª | « | ¬ | ® | ¯ | ° | ± | ² | ³ | ´ | µ | ¶ | · | ¸ | ¹ | º | » | ¼ | ½ | ¾ | ¿ | |||
| 00C0 | À | Á | Â | Ã | Ä | Å | Æ | Ç | È | É | Ê | Ë | Ì | Í | Î | Ï | Ð | Ñ | Ò | Ó | Ô | Õ | Ö | × | Ø | Ù | Ú | Û | Ü | Ý | Þ | ß | Latin |
| 000E | à | á | â | ã | ä | å | æ | ç | è | é | ê | ë | ì | í | î | ï | ð | ñ | ò | ó | ô | õ | ö | ÷ | ø | ù | ú | û | ü | ý | þ | ÿ | |
| 0100 | Ā | ā | Ă | ă | Ą | ą | Ć | ć | Ĉ | ĉ | Ċ | ċ | Č | č | Ď | ď | Đ | đ | Ē | ē | Ĕ | ĕ | Ė | ė | Ę | ę | Ě | ě | Ĝ | ĝ | Ğ | ğ | |
| 0120 | Ġ | ġ | Ģ | ģ | Ĥ | ĥ | Ħ | ħ | Ĩ | ĩ | Ī | ī | Ĭ | ĭ | Į | į | İ | ı | IJ | ij | Ĵ | ĵ | Ķ | ķ | ĸ | Ĺ | ĺ | Ļ | ļ | Ľ | ľ | Ŀ | |
| 0140 | ŀ | Ł | ł | Ń | ń | Ņ | ņ | Ň | ň | ʼn | Ŋ | ŋ | Ō | ō | Ŏ | ŏ | Ő | ő | Œ | œ | Ŕ | ŕ | Ŗ | ŗ | Ř | ř | Ś | ś | Ŝ | ŝ | Ş | ş | |
| 0160 | Š | š | Ţ | ţ | Ť | ť | Ŧ | ŧ | Ũ | ũ | Ū | ū | Ŭ | ŭ | Ů | ů | Ű | ű | Ų | ų | Ŵ | ŵ | Ŷ | ŷ | Ÿ | Ź | ź | Ż | ż | Ž | ž | ſ | |
| 0180 | ƀ | Ɓ | Ƃ | ƃ | Ƅ | ƅ | Ɔ | Ƈ | ƈ | Ɖ | Ɗ | Ƌ | ƌ | ƍ | Ǝ | Ə | Ɛ | Ƒ | ƒ | Ɠ | Ɣ | ƕ | Ɩ | Ɨ | Ƙ | ƙ | ƚ | ƛ | Ɯ | Ɲ | ƞ | Ɵ | |
| 01A0 | Ơ | ơ | Ƣ | ƣ | Ƥ | ƥ | Ʀ | Ƨ | ƨ | Ʃ | ƪ | ƫ | Ƭ | ƭ | Ʈ | Ư | ư | Ʊ | Ʋ | Ƴ | ƴ | Ƶ | ƶ | Ʒ | Ƹ | ƹ | ƺ | ƻ | Ƽ | ƽ | ƾ | ƿ | |
| 01C0 | ǀ | ǁ | ǂ | ǃ | DŽ | Dž | dž | LJ | Lj | lj | NJ | Nj | nj | Ǎ | ǎ | Ǐ | ǐ | Ǒ | ǒ | Ǔ | ǔ | Ǖ | ǖ | Ǘ | ǘ | Ǚ | ǚ | Ǜ | ǜ | ǝ | Ǟ | ǟ | |
| 100E | Ǡ | ǡ | Ǣ | ǣ | Ǥ | ǥ | Ǧ | ǧ | Ǩ | ǩ | Ǫ | ǫ | Ǭ | ǭ | Ǯ | ǯ | ǰ | DZ | Dz | dz | Ǵ | ǵ | Ƕ | Ƿ | Ǹ | ǹ | Ǻ | ǻ | Ǽ | ǽ | Ǿ | ǿ | |
| 200 | Ȁ | ȁ | Ȃ | ȃ | Ȅ | ȅ | Ȇ | ȇ | Ȉ | ȉ | Ȋ | ȋ | Ȍ | ȍ | Ȏ | ȏ | Ȑ | ȑ | Ȓ | ȓ | Ȕ | ȕ | Ȗ | ȗ | Ș | ș | Ț | ț | Ȝ | ȝ | Ȟ | ȟ | |
| 0220 | Ƞ | ȡ | Ȣ | ȣ | Ȥ | ȥ | Ȧ | ȧ | Ȩ | ȩ | Ȫ | ȫ | Ȭ | ȭ | Ȯ | ȯ | Ȱ | ȱ | Ȳ | ȳ | ȴ | ȵ | ȶ | ȷ | ȸ | ȹ | Ⱥ | Ȼ | ȼ | Ƚ | Ⱦ | ȿ | |
| 0240 | ɀ | Ɂ | ɂ | Ƀ | Ʉ | Ʌ | Ɇ | ɇ | Ɉ | ɉ | Ɋ | ɋ | Ɍ | ɍ | Ɏ | ɏ | ɐ | ɑ | ɒ | ɓ | ɔ | ɕ | ɖ | ɗ | ɘ | ə | ɚ | ɛ | ɜ | ɝ | ɞ | ɟ | |
| 0260 | ɠ | ɡ | ɢ | ɣ | ɤ | ɥ | ɦ | ɧ | ɨ | ɩ | ɪ | ɫ | ɬ | ɭ | ɮ | ɯ | ɰ | ɱ | ɲ | ɳ | ɴ | ɵ | ɶ | ɷ | ɸ | ɹ | ɺ | ɻ | ɼ | ɽ | ɾ | ɿ | |
| 0280 | ʀ | ʁ | ʂ | ʃ | ʄ | ʅ | ʆ | ʇ | ʈ | ʉ | ʊ | ʋ | ʌ | ʍ | ʎ | ʏ | ʐ | ʑ | ʒ | ʓ | ʔ | ʕ | ʖ | ʗ | ʘ | ʙ | ʚ | ʛ | ʜ | ʝ | ʞ | ʟ | |
| 02A0 | ʠ | ʡ | ʢ | ʣ | ʤ | ʥ | ʦ | ʧ | ʨ | ʩ | ʪ | ʫ | ʬ | ʭ | ʮ | ʯ | ʰ | ʱ | ʲ | ʳ | ʴ | ʵ | ʶ | ʷ | ʸ | ʹ | ʺ | ʻ | ʼ | ʽ | ʾ | ʿ | |
| 02C0 | ˀ | ˁ | ˂ | ˃ | ˄ | ˅ | ˆ | ˇ | ˈ | ˉ | ˊ | ˋ | ˌ | ˍ | ˎ | ˏ | ː | ˑ | ˒ | ˓ | ˔ | ˕ | ˖ | ˗ | ˘ | ˙ | ˚ | ˛ | ˜ | ˝ | ˞ | ˟ | |
| 200E | ˠ | ˡ | ˢ | ˣ | ˤ | ˥ | ˦ | ˧ | ˨ | ˩ | ˪ | ˫ | ˬ | ˭ | ˮ | ˯ | ˰ | ˱ | ˲ | ˳ | ˴ | ˵ | ˶ | ˷ | ˸ | ˹ | ˺ | ˻ | ˼ | ˽ | ˾ | ˿ | |
| 0300 | ̀ | ́ | ̂ | ̃ | ̄ | ̅ | ̆ | ̇ | ̈ | ̉ | ̊ | ̋ | ̌ | ̍ | ̎ | ̏ | ̐ | ̑ | ̒ | ̓ | ̔ | ̕ | ̖ | ̗ | ̘ | ̙ | ̚ | ̛ | ̜ | ̝ | ̞ | ̟ | |
| 0320 | ̠ | ̡ | ̢ | ̣ | ̤ | ̥ | ̦ | ̧ | ̨ | ̩ | ̪ | ̫ | ̬ | ̭ | ̮ | ̯ | ̰ | ̱ | ̲ | ̳ | ̴ | ̵ | ̶ | ̷ | ̸ | ̹ | ̺ | ̻ | ̼ | ̽ | ̾ | ̿ | |
| 0340 | ̀ | ́ | ͂ | ̓ | ̈́ | ͅ | ͆ | ͇ | ͈ | ͉ | ͊ | ͋ | ͌ | ͍ | ͎ | ͏ | ͐ | ͑ | ͒ | ͓ | ͔ | ͕ | ͖ | ͗ | ͘ | ͙ | ͚ | ͛ | ͜ | ͝ | ͞ | ͟ | |
| 0360 | ͠ | ͡ | ͢ | ͣ | ͤ | ͥ | ͦ | ͧ | ͨ | ͩ | ͪ | ͫ | ͬ | ͭ | ͮ | ͯ | Ͱ | ͱ | Ͳ | ͳ | ʹ | ͵ | Ͷ | ͷ | | | ͺ | ͻ | ͼ | ͽ | ; | Ϳ | |
| 0380 | | | | | ΄ | ΅ | Ά | · | Έ | Ή | Ί | | Ό | | Ύ | Ώ | ΐ | Α | Β | Γ | Δ | Ε | Ζ | Η | Θ | Ι | Κ | Λ | Μ | Ν | Ξ | Ο | Greek |
| 03A0 | Π | Ρ | | Σ | Τ | Υ | Φ | Χ | Ψ | Ω | Ϊ | Ϋ | ά | έ | ή | ί | ΰ | α | β | γ | δ | ε | ζ | η | θ | ι | κ | λ | μ | ν | ξ | ο | |
| 03C0 | π | ρ | ς | σ | τ | υ | φ | χ | ψ | ω | ϊ | ϋ | ό | ύ | ώ | Ϗ | ϐ | ϑ | ϒ | ϓ | ϔ | ϕ | ϖ | ϗ | Ϙ | ϙ | Ϛ | ϛ | Ϝ | ϝ | Ϟ | ϟ | |
| 300E | Ϡ | ϡ | Ϣ | ϣ | Ϥ | ϥ | Ϧ | ϧ | Ϩ | ϩ | Ϫ | ϫ | Ϭ | ϭ | Ϯ | ϯ | ϰ | ϱ | ϲ | ϳ | ϴ | ϵ | ϶ | Ϸ | ϸ | Ϲ | Ϻ | ϻ | ϼ | Ͻ | Ͼ | Ͽ |