3 Phase Full Wave Diode Rectifier (Equations And Circuit Diagram)

💡
Key learnings:
  • 3 Phase Full Wave Rectifier Definition: A 3-phase full-wave diode rectifier combines two half-wave rectifiers to produce a lower ripple DC output.
  • Circuit Diagram: Includes six diodes arranged to rectify the three-phase AC input into a smoother DC output.
  • Diode Conduction: Each diode conducts for 120 degrees, and diode pairs conduct for 60 degrees.
  • Output Ripple Frequency: The output voltage has a 300Hz ripple, which is six times the input AC frequency.
  • Peak Inverse Voltage (PIV): The maximum reverse voltage a diode can withstand is √3 times the maximum phase voltage.

What is a Three Phase Full Wave Diode Rectifier?

A three-phase full-wave diode rectifier (six-pulse bridge) is obtained by using two half-wave rectifier circuits. The DC voltage has six pulses per AC cycle, so the ripple frequency is six times the AC frequency and is lower than that of a three-phase half-wave rectifier.

Three Phase Full Wave Diode Rectifier
Three Phase Full Rectified Wave

A three-phase full-wave diode rectifier with purely resistive load is shown below. The AC voltage supply in this example is 110 V line to line and 50 Hz frequency.

The voltage waveform across the load is shown in black in the figure. Vm-phase is the maximum phase voltage, and the minimum voltage across the load is 1.5 times Vm-phase.

In the circuit, diode D1 begins conducting at 30°, when the R phase becomes the most positive. The R-phase peak is at 90°. Diode D1 stops at 150°, and diode D3 takes over when the Y phase becomes the most positive.

Diode D1 conducts from 30° to 150° during the positive cycle, assisted by diode D6, which completes the return path to the three-phase source. Diode D6 carries the negative-rail current until 90°, when diode D2 takes over and completes the path with diode D1.

  • Therefore each diode pair conducts for 60o, and each diode conducts for 120o.
  • The load voltage has a ripple, and the frequency of this ripple is 6 × 50 = 300 Hz for the 50 Hz example above. In general it is 6f.

The magnitude of the DC voltage is the sum of the magnitude of the voltages in the two diodes that are conducting at any instant, which is incidentally also a particular line voltage depending on which diode pair is conducting.
The average of the output voltage across the resistive load is given by

where,

The RMS value of the output voltage is given by

Ripple voltage,
Voltage ripple factor,
DC output power,
AC input power,
Efficiency,
The voltage and current across the diode D1 are as shown below.

We can see from the voltage waveform above that the PIV, Peak Inverse Voltage, which is the maximum voltage faced by the diode when reverse biased, is √3 Vm-phase.