01․ In parallel RLC circuit under resonance condition the value of current is
In RLC parallel circuit under resonance condition the value of inductive susceptance is equal to capacitive susceptance and they will cancel each other. Therefore the value of admittance is minimum and impedance is maximum. Hence current is minimum in this condition.
02․ For ideal tank circuit, what is the value of dynamic admittance?
03․ For ideal tank circuit what is the value of dynamic impedance?
04․ In series RLC circuit to get Q>1, which of the following is required?
05․ In RLC parallel circuit to get Q>1 which of the following is required?
06․ By which of the following elements transients will not occur?
Resistance will not store the energy and it will allow sudden changes of voltage or current. Therefore transients will not occur in resistance. Transients will occur in inductance and capacitance only.
07․ Which of the following elements is/are called dynamic element/s?
Dynamic elements are nothing but energy storage elements, which will show transient response when they are connected to DC or AC.
08․ For steady state current inductor acts as
09․ In RL series circuit R=2Ω and L=10mH and applied voltage is 10V DC. Then find the current in the network?
For DC voltage inductor acts as a short circuit at steady state.
10․ In steady state condition capacitor acts as a