01․ The phase angle difference between current and voltage is 90o, the power will be
The expression of active power P = VIcosθ .
Where, V is voltage, I is current and θ is the angle between current and voltage. Here, this θ = 90o.
∴ Power P = VIcos90o = 0. (Since, cos90o = 0)
02․ Kirchhoffs laws are valid for
Linear circuits obey Ohms law. Kirchhoffs laws are valid for those elements that obey Ohms law.
03․ For the circuit shown below the value of R is adjusted so as to make the current in RL equal to zero. Calculate the value of R.
04․ In the circuit shown in figure if I1 = 1.5 A, then I2 will be


Applying KVL in the loops,
i1 = I1 =I2 and i2 = 0. So I2 = 1.5 A.05․ In the circuit shown in the figure the voltage across the 2 Ω resistor is
06․ The value of current I flowing in the 1 Ω resistor in the circuit shown in the given figure will be
5A current flows through the 1 Ohm resistor as no current flows to the voltage source.
07․ The voltage across the 1 Ω resistor between the nodes A and B of the network shown in the given figure is
Applying KCL at node A, VA = 2V.
08․ In the network shown, what is the current I in the direction shown?

09․ An electrical circuit with 10 branches and 7 nodes will have
Number of loop equations = branches - nodes + 1 = b - n + 1 = 10 - 7 + 1 = 4 loop equations.
10․ In given figure, the value of resistance R in Ω is


The given circuit can be simplified by replacing voltage source by equivalent current source as below,
The current through 5 Ω resistor is 8 A hence voltage across it is 8 X 5 = 40 V and this is the voltage across unknown resistor R. As current through R is 2 A.

The current through 5 Ω resistor is 8 A hence voltage across it is 8 X 5 = 40 V and this is the voltage across unknown resistor R. As current through R is 2 A.